CLOGP Error Codes

The ClogP error codes are:

0

All fragments measured

1-10

Trusted fragment value used

11-18

Largest disconnected structure used

19

Valid estimate for difficult structure

20-29

Estimated fragment value used

30

Approximated fragment value used

31

Benzyl approximation used

32

Vinyl approximation used

33-39

New approximated fragment value used

40

a priori fragment value used

41

Benzyl approximation based on a priori value

42

Vinyl approximation based on a priori value

43-49

Other a priori value used

50

Warning, hard to estimate structure

51

Very high logP unrealistic in nature

52

"X/Y-C-C-Y" excessive structure

53-54

Possibly low due to hydrophilic overlap

55

Valid estimate for steroid

56

Valid estimate for alkaloid

57

Error uncertain for charged structures

58-59

(NEW) STRUCTURE CAUGHT IN SCREEN (estimated fragment values were used)

60

Invalid due to missing fragment value

61-70

Apparent impossible structure

71

ClogP can't do disconnected structures

72-79

Apparent impossible structure

80

Invalid smiles input (fatal)